共检索到 2

The seismic damage of underground structures has been extensively investigated, and it has been demonstrated that underground structures located at weak interlayer sites are more prone to damage. In this study, a two-story two-span rectangular frame subway station structure is analyzed. A two-dimensional soil-underground structure model is developed using the large-scale finite element analysis software ABAQUS. The equivalent linear soil-underground structure dynamic time-history analysis method is employed to examine the seismic response of underground structures at weak interlayer sites. Variations in the thickness and shear wave velocity of the weak interlayer soil are analyzed. The seismic mitigation effects of split columns and prototype columns in underground structures at weak interlayer sites are systematically compared. The findings indicate that the relative displacement and internal force of key structural components significantly increase when the weak interlayer intersects the underground structure. Furthermore, as the thickness of the interlayer increases, the displacement and internal force also escalate. When the thickness of the weak interlayer remains constant and the shear wave velocity decreases, the relative displacement and internal force of the key structural components gradually intensify. Replacing ordinary columns with split columns substantially reduces the internal force of the middle column, providing an effective seismic mitigation measure for underground structures.

期刊论文 2025-01-01 DOI: 10.3390/app15020798

The behavior of center columns in shallow-buried underground subway station structures resembles that of high-rise buildings. In both cases, these columns experience significant vertical loads during earthquake events and are susceptible to brittle failure due to inadequate deformation capacity. In this study, the design concept of split columns, commonly employed in high-rise structures, is adapted for application in a two-story, two-span subway station. Initially, a comparative analysis was conducted using quasi-static pushover analysis to assess the horizontal deformation characteristics of traditional and split columns under high axial loads. Subsequently, a comprehensive quasi-static pushover analysis model encompassing the soil-structure interaction was formulated. This model was employed to investigate differences in seismic performance between traditional and innovative underground structures, considering internal forces, deformation capacity, and plastic damage of crucial elements. The analysis results demonstrate that the incorporation of split columns in a two-story, two-span subway station enhances the overall seismic performance of the structure. This enhancement arises from the fact that split columns mitigate excessive shear forces while effectively utilizing their vertical support and horizontal deformation capacities.

期刊论文 2024-05-01 DOI: 10.3390/app14104077
  • 首页
  • 1
  • 末页
  • 跳转
当前展示1-2条  共2条,1页